facebook_pixelATC-300+ CONTROLLER - GRUPOS GERADORES | Projectista
STET

ATC-300+ CONTROLLER - GRUPOS GERADORES

  • ColeçãoColeçãoGRUPOS GERADORES
carousel

Descrição

The ATC-300+ is a comprehensive and multifunctional microprocessor-based ATS controller. It is a compact and self-contained panel-mounted device that is designed to replace traditional relay and solid-state logic panels. The ATC-300+ Controller provides programmed flexibility to address the needs of any system. It operates from all system voltages between 120 to 600V, single-phase and three-phase at 50 or 60 Hz. In addition, a period of no control power is provided. The controller monitors the condition of the three-phase line-to-line voltage and frequency of Source 1 and Source 2 power sources and can be programmed for single-phase operation. The ATC-300+ Controller provides the intelligence to ensure that the ATS operates properly through a series of programmed sensing and timing functions.

Informações Tećnicas

  • Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
  • Transfer Type: Switch application dependent
  • Switch Type: Switch application dependent

Mais informações

Technical Summary

  • Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
  • Transfer Type: Switch application dependent
  • Switch Type: Switch application dependent

ATC Controller Specifications

  • Input Control Voltage: 65 to 145 Vac 50/60 hZ
  • Voltage Measurements of Utility: Source 1 VAB Source 2 VABSource 1 VAC Source 2 VBCSource 1 VCA Source 2 VCA
  • Voltage Measurement Range: 0 to 790 VAC rms (50/60 Hz)
  • Voltage Measurement Accuracy: +/-2% of nominal input voltage
  • Frequency Measurements Of: Source 1 and Source 2
  • Frequency Measurement Range: 40 Hz to 70 Hz
  • Frequency Measurement Accuracy: +/- 0.1 Hz
  • Undervoltage Dropout: 50% to 90% of nominal voltage
  • Undervoltage Pickup: (Dropout +2%) to 99% of the nominal system voltage
  • Underfrequency Dropout Range: 90 to 97% of the nominal system frequency
  • Underfrequency Pickup Range: (Dropout +1 Hz) to 99% of the nominal system frequency
  • Overfrequency Dropout Range: 103 to 110% of the nominal system frequency
  • Overfrequency Pickup Range: 101% to (dropout - 1 Hz) of the nominal system frequency
  • Operating Temperature Range: -20 to 70 degree C (-4 to +158 degree F)
  • Storage Temperature Range: -30 to 85 degree C (-22 to +185 degree F)
  • Operating Humidity: 0 to 95% relative humidity (noncondensing)
  • Operating Environment: Resistant to ammonia, methane, nitrogen,hydrogen and hydrocarbons
  • Generator Start Relay: 5A, 1/6 hp @ 250 Vac Vac 5A @ 30 Vdc with a 150W maximum load
  • K1, K2 Relays: 10A, 1-3 hp @ 250 Vac10A@30 Vdc
  • Applicable Testing: UL-recognized componentMeets intent of UL 991 & UL 1008Meets IEC 1000-4-2, 1000-4-3, 1000-4-4
  • Applicable Testing Continued: 1000-4-5, 1000-4-6, 1000-4-11CISPR 11, Class AFCC Part 15, Class ACSS 22.2-178
  • Enclosure Compatibility: NEMA 1, NEMA 3R and NEMA 12UV-resistant ATC-300+ faceplate